Gas Chromatographic Method for Quantification of Gasoline and BTEX in Water Samples

Paper Details

Research Paper 01/04/2016
Views (238) Download (15)
current_issue_feature_image
publication_file

Gas Chromatographic Method for Quantification of Gasoline and BTEX in Water Samples

Ghazala Yaqub, Shanzay Asad, Haseeb Akram
J. Bio. Env. Sci.8( 4), 244-251, April 2016.
Certificate: JBES 2016 [Generate Certificate]

Abstract

This study was conducted with the aim to determine concentration of benzene, toluene, ethyl benzene, xylene and gasoline in different water samples (drinking water, drain water and canal water) of dry port and surrounding residential area as Presence of excess these compounds in water pose many health problems like cancer, gastroenteritis, dysentery, diarrhea and viral hepatitis. Firstly, physical parameters (pH, turbidity, TSS and TDS) were analyzed as the analysis of these parameters is keen important to get an idea of any organic contamination in water and then in second step selective an sensitive approach of gas chromatography was used for the qualitative and quantitative determination of these compounds. Gasoline was detected in about all samples except one waste water sample. The detected concentrations of gasoline were 8503.2, 568.19, 11546.51, 345.29, 4042.82, 2835.67 and 182.96 ppm. Benzene was detected in all samples in concentrations of 1, 0.007, 391.11, 485.16,121.73,421.23, 183.88, 38.14, 138.12 and 306.87 ppm. Toluene was detected in all samples except one waste water sample and two canal water samples. Detected concentrations of Toluene were 20.45, 160.82, 64.47, 7.34 and 15.5 ppm. Moreover, xylene was not detected in any of the sample. BTEX and gasoline were detected in water samples in concentration exceeding the limits set by WHO and NEQS standards thus posing significant effects towards environment and health.

VIEWS 28

Assadi P, AshtariK, Hosseini MH, Rezaei MR, Rezaee M. 2014. Development of homogenous Liquid – Liquid microextraction via flotation assistance method for determination of Benzene, Toluene, Xylene and styrene in water samples. Iranian Journal of Analytical Chemistry 1, 20-28.

Agapova N, Winkler I.2010. Determination of water pollution by the oil products through UV photometry. Journal of Environmental monitoring 168(1-4), 115-9.

Aurel N, Elda M, Bledar M. 2014. Detection of PAH and BTEX levels in water samples using GC/FID techniques:   case   study   of   POTKU   LAGOON. International  Journal  of  Ecosystem  and  Ecology Science 4(2), 195

Ong  CP,  Ng  CL,  Chong  NC,  Lee  HK. 1991. Analysis   of   Priority   Substituted   Phenols by Micellar Electro kinetic Chromatography. Environmental monitoring and assessment 19(1-3), 93-103.

Michael B, Frederic L. 2010. A short primer on benzene, toluene, ethylbenzene and xylenes (BTEX) in  the  environment  and  in  hydraulic  fracturing fluids.Retrieved March 2nd,2016 from

Mclntyre  A,  Rome  K.  2012.Intelligent  use  of relative response factor in gas chromatography-Flame ionization detection chromatography. Chromatography Today. 52-55.

U.S Department of Health and Service. 1994. Toxicological profile for gasoline. Retrieved June 22, 2015

U.S.   Environmental Protection   Agency. 2012.Toluene  Hazard  SummaryRetrived  on  march 29th, 2015

Zaikowski L. The  Encyclopedia  of  Earth.  2008. Health effects of toluene. Retrieved on April 2nd, 2015 from.